Shopping cart icon
Hyperlight Therapy

BIOPTRON Pro1

 

PAG-990

Our medical light technology is based on Nobel Prize winning technology, and is fully certified for non-invasive, accelerated healing and medical prevention of a wide range of conditions including: acne, skin wounds, sports injuries, anti-aging, arthritic and low back pain. Just 5 to 10 minutes of treatment with BIOPTRON twice a day is all that is needed for accelerated healing. BIOPTRON Pro1 has a filter diameter of 11cm and is designed for use at home, in hospitals and in therapeutic centers.
Read More
RRP Price € 2700.00
ZepterClub member -20% € 2160.00
ZepterClub partner -20% € 2160.00
Delivery up to 7 business days

Overview

Our medical light technology is based on Nobel Prize winning technology, and is fully certified for non-invasive, accelerated healing and medical prevention of a wide range of conditions including: acne, skin wounds, sports injuries, anti-aging, arthritic and low back pain. Just 5 to 10 minutes of treatment with BIOPTRON twice a day is all that is needed for accelerated healing. BIOPTRON Pro1 has a filter diameter of 11cm and is designed for use at home, in hospitals and in therapeutic centers.

Presentation

BIOPTRON: BEAUTY & HEALTH REBORN  


30 years of intensive research, hundreds of clinical trials, and significant investment make BIOPTRON the world’s leading Light Device for health and beauty. Small yet powerful, the Swiss-made BIOPTRON MedAll light system is clinically proven and certified across the world, for faster healing and pain relief of medical conditions. Easy to use and absolutely safe, the deeply penetrating hyper-polarized medical device is designed for use at home, but can also be used by healthcare professionals in hospitals, clinics, and wellness/sports centers. Importantly, the 100% safe spectrum of BIOPTRON polychromatic light does not contain any UV radiation.


Pain Relief
 
  • Osteoarthritis,
  • Arthrosis,
  • Low back pain,
  • Shoulder and neck pain,
  • Scar tissue,
  • Musculoskeletal injuries,
  • Carpal tunnel syndrome,
  • Sports medicine - soft tissue injuries of muscles, tendons and ligaments,
  • Muscle spasm,
  • Sprains, strains, contusions,
  • Desmorrhexis and myorrhexis {ligament and muscle tear),
  • Tendonitis,
  • Epicondylitis {tennis-ellbow).
 
Recommended treatment time I distance for pain treatment: 4 - 10 minutes I 10 cm.
 
The promotion of wound healing in the following indications
 
  • Injuries/ Trauma,
  • Operations {incision),
  • Burns,
  • Grafting,
  • Venous leg ulcers {stasis ulcer),
  • Decubitus {pressure sores),
 
Recommended treatment time/ distance for wound healing: 2 - 8 minutes/ 10 cm.
 
Dermatological disorders and skin problems in the following indications
 
  • Atopic dermatitis,
  • Psoriasis,
  • Herpes simplex & zoster,
  • Superficial bacterial infections,
  • Acne,
  • Mucosal lesions.
 
Recommended treatment time/ distance for pain treatment: 4 - 10 minutes/ 10 cm.
 
 
Additional indications for children
 
  • Pediatric dermal affections,
  • Endogenous eczema,
  • Upper respiratory tract infections,
  • Allergic respiratory diseases,
  • Pediatric musculoskeletal and neurological disorders and deficits.
 
Recommended treatment time I distance for dermatological diseases: 4 - 10 minutes/ 10 cm.

IMPORTANT: A special blindfold is required for the use of Bioptron Hyperlight devices in newborns.You'll receive a Voucher included with your device for a complimentary blindfold, redeemable for free at any Zepter showroom or office. Do not use the device on newborns until you have the blindfold. Consult a doctor before use. For children under six years old, a physician must supervise its application. If needed, you can purchase more blindfolds HERE.

 
Additional indications for newborns
 
  • Dermal affections as phlebitis, decubitus, intertrigo.
 
Recommended treatment time I distance for dermatological diseases: 4 - 10 minutes I 10 cm..
 
Seasonal affective disorders (SAD)
 
  • Typical winter depression symptoms as chronic fatigue syndrome, lowered motivation, hypersomnia, asthenic conditions, break down.
 
Recommended treatment times/ distances for SAD: 20 - 40 minutes at 20 cm, 40 - 60 minutes at 30 cm or 60 - 120 minutes at 40 cm.

Tech Data

Item code
PAG-990
Product name
BIOPTRON Pro1
Warranty
5 years
Gross weight [KG]
4.6
Net weight [KG]
3.5
Safety class
IIa
Application
BIOPTRON improves microcirculation • Reinforces the body’s defense system • Stimulates regenerative and reparative processes • Promote wound healing • Relieve pain or decrease its intensity - these basic mechanisms are responsible for the therapeutic healing effects as a complementary treatment of the following medical conditions: pain, wounds, dermatology, pediatrics, SAD
Dimensions
40 x 30 x 49 cm
Producer
BIOPTRON AG - Sihleggstrasse 23, CH-8832 Wollerau - Switzerland
Made in
Switzerland
Voltage
Power supply 100-240 V~, 50/60 Hz
Rated Power consumption
75 W
Rated power of halogen
50 W
Power cord
detachable (3m)
Light energy per minute
an av. of 2.4 J/cm2
Power density
on av. of 40 mW/cm²
Wavelength
350 - 3400 nm
Degree of polarization
>95%
Composition
BIOPTRON PRO1 device * Table stand * Power cord (detachable) * Protective cover * Protective bag * Oxy Sterile Spray voucher * User manual * Warranty
Display
Yes digital
Certifications/Declaration
EC Certificate, MDSAP, 510(k)
Safety Instructions
Risk of electric shock
WARNING: do not leave the equipment unattended when it is switched on to avoid the risk of fire or burns.

WARNING: water and electricity are a dangerous combination! To avoid risk of electrocution,
do not use this equipment in wet surroundings (e.g. in the bathroom or near a shower or swimming pool);
do not let water run into the appliance.

Read more
Danger of electric shock! Keep dry! NEVER immerse in water! Do not open the appliance!
Unplug the device if any liquids or particles enter the device. Contact your service center.
Never block the ventilation slits of the device.
WARNING: if the mains cord is damaged, you shall have it replaced by BIOPTRON AG, a service center authorized by BIOPTRON AG or similarly qualified persons in order to avoid risk of electrocution.
WARNING: if the wall socket used to power the equipment has poor connections, the plug of the equipment becomes hot. Make sure you plug the equipment into a properly installed wall socket to avoid the risk of fire and burns.
CAUTION: always unplug the appliance after use and in case of a power failure to avoid risk of damage to the equipment.
CAUTION: do not subject the equipment to heavy shocks to avoid risk of damage to the lamp.
Never operate a damaged device (cables, plugs, housing or optical component).

OPTICAL RADIATION APERTURE • RISK GROUP 2
CAUTION: IR emitted from this device may cause eye irritation. Do not stare at the light source. If not respected eye damage may occur. For the treatment of the eye area, remove contact lenses and keep your eyes closed.
CAUTION: use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Repairs and replacements of the halogen bulb should only be conducted by BIOPTRON-authorised service centres!
Do not carry out repairs yourself!
No modification of this equipment is allowed! Danger if non-genuine substitute parts are used.
Please use only BIOPTRON cable, other cables may negatively affect safety and/or performance. The power cable poses a strangulation hazard to children.
Should you encounter an unexpected failure, product-related problems and/or incident while setting up, using, or maintaining your BIOPTRON Medical Device, please contact your BIOPTRON Service Center. Any serious incident that has occurred in relation to the device should be reported to the manufacturer (Bioptron AG contact on the cover) and the competent authority of the Member State in which the user and/or patient is established.
WARNING: this equipment is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the equipment to avoid the risk of fire or burns.
WARNING: this equipment is not intended for use by children. Children should be supervised to ensure that they do not play with the equipment to avoid the risk of fire and burns.
Medical device is not intended to use in oxygen rich environment and with flammable anaesthetics. In order to fulfil and retain the stability of the Floor Stand the handling of locking pin and nozzle (middle and end of vertical rod) must be done carefully and should be implemented by two persons.
Do not stand or kneel on the table stand.

Related products

Zepter logotype Product was successfully added to your shopping cart! Bags Go to cart